Model Name | MIN 2500TL-X2 | MIN 3000TL-X2 | MIN 3600TL-X2 | MIN 4200TL-X2 | MIN 4600TL-X2 | MIN 5000TL-X2 | MIN 6000TL-X2 |
Input Data (DC) | |||||||
Max. recommended PV power (for module STC) | 3750W | 4500W | 5400W | 6300W | 6900W | 7500W | 9000W |
Max. DC voltage | 500V | 500V | 550V | 550V | 550V | 550V | 550V |
Start voltage | 50V | ||||||
Nominal voltage | 360V | ||||||
MPP voltage range | 40V-500V | 40V-500V | 40V-550V | 40V-550V | 40V-550V | 40V-550V | 40V-550V |
No. of MPP trackers | 2 | ||||||
No. of PV strings per MPP trackers | 1 | ||||||
Max. input current per MPP tracker | 16A | ||||||
Max. short-circuit current per MPP tracker | 24A | ||||||
Output data (AC) | |||||||
AC nominal power | 2500W | 3000W | 3600W | 4200W | 4600W | 5000W | 6000W |
Max. AC apparent power | 2500VA | 3000VA | 3600VA | 4200VA | 4600VA | 5000VA | 6000VA |
Nominal AC voltage (range*) | 230V (160-300V) | ||||||
AC grid frequency (range*) | 50/60 Hz (45-55Hz/54-65 Hz) | ||||||
Max. output current | 11.3A | 13.6A | 16A | 19A | 20.9A | 22.7A | 27.2A |
Adjustable power factor | 0.8leading…0.8lagging | ||||||
THDi | <3% | ||||||
AC grid connection type | Single phase | ||||||
Efficiency | |||||||
Max.efficiency | 98.2% | 98.2% | 98.2% | 98.4% | 98.4% | 98.4% | 98.4% |
European efficiency | 97.1% | 97.1% | 97.2% | 97.2% | 97.5% | 97.5% | 97.5% |
MPPT efficiency | 99.9% | ||||||
Protection Devices | |||||||
DC reverse polarity protection | Yes | ||||||
DC switch* | Yes | ||||||
DC surge protection | Type II | ||||||
Insulation resistance monitoring | Yes | ||||||
AC surge protection | Type III | ||||||
AC short-circuit protection | Yes | ||||||
Grid monitoring | Yes | ||||||
Anti-islanding protection | Yes | ||||||
Residual-current monitoring unit | Yes | ||||||
AFCI protection | Optional | ||||||
General Data | |||||||
Dimensions (W / H / D) | 375/350/158mm | ||||||
Weight | 10.8kg | ||||||
Operating temperature range | –30°C ... +60°C | ||||||
Nighttime power consumption | <1W | ||||||
Topology | Transformerless | ||||||
Cooling | Natural convection | ||||||
Protection degree | IP66 | ||||||
Relative humidity | 0-100% | ||||||
Altitude | 4000m | ||||||
DC connection | H4/MC4(Optional) | ||||||
AC connection | Connector | ||||||
Display | OLED+LED | ||||||
Interfaces: RS485 /USB/Wi-Fi/GPRS/ RF/LAN | Yes/Yes/Optional/Optional/Optional/Optional | ||||||
Warranty: 5 years / 10 years | Yes /Optional |